Changes for page CQM Requirements - Change History
Last modified by Uwe Trueggelmann on 2025/02/15 00:20
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -43,21 +43,20 @@ 43 43 44 44 * //#0654#: Design and Development – Product Qualification Report// — Lack of qualification data, and major NC without CSI letter now prohibit CQM certification 45 45 * IQC (Incoming Quality Control) to be assessed during CQM Audits for each CQM product and component, and not just once as part of the QMS 46 -* //#0662#: Requirements for Products and Services – Determining the Requirements for Products and Services, Order Specification// — Order Specification appended to title to clarify that an Order Specification is required, verbiage added to clarify Order Specification 47 47 * //#0703# Release of Product and Services, Batch Yield Limit// — split into two independent requirements: //#0703#: Production and Service Provision – Release of Product and Services// and //#0707#: Production and Service Provision – Batch Yield Limit//; Batch Yield Limit now only applicable to products containing an IC. 48 48 * Requirements to implement SPC (//#0705#: Performance evaluation – Statistical Process Control//) and CpK (//#0811#: Performance evaluation – Process Capability//) restricted to ic icm iacicm bsm il iacil iac, that is, where processes involve wafer processing or IC packaging processes. 49 49 50 50 === Product Requirements === 51 51 52 -* #3046#:Resistance to Chemicals— For CQM productsandcomponentswhere// #3058#: Solidity – Adhesion of ICM to Card// is required,clarified thatone sample per solution shall be tested for //#3058#: Solidity – Adhesion of ICM to Card//53 -* //#3050#: ESD Conductivity – ESC — //Increased permitted levels of ESD conductivity54 -* //#3067#: Suitability for an Identification Notch —//Permitting greater tolerances55 -* //#3110#: IAC – Interactive Cards – Requirement to maintain a valid CSI Letter// —restricted to specific products, clarified to which products and components this requirement still applies.56 -* //#3120#: Pilot, innovative, and interactive cardholder identification products //– //requirement to undergo CQM Audits depending on annual production volume//— New requirement easing CQM audit and CQM certification requirements for innovative and interactive cardholder products with very small volumes.57 -* //#3130#: Products that are not compliant with applicable CQM requirements – Requirement to maintain a valid CSI Letter// — Now anindividual requirement to clarifybetter that CQM non conformities must be covered by a CSI letter.51 +* For cards, when testing Resistance to Chemicals, clarified that where// #3058#: Solidity – Adhesion of ICM to Card// is required, one sample per solution shall be tested for //#3058#: Solidity – Adhesion of ICM to Card// 52 +* Increased permitted levels of ESD conductivity for //#3050#: ESD Conductivity — ESC// 53 +* Permitting greater tolerances in //#3067#: Suitability for an Identification Notch// 54 +* //#3110#: IAC – Interactive Cards – Requirement to maintain a valid CSI Letter// restricted to specific products, clarified to which products and components this requirement still applies. 55 +* Added //#3120#: Pilot, innovative, and interactive cardholder identification products requirement to undergo CQM Audits depending on annual production volume//, easing CQM audit and CQM certification requirements for innovative and interactive cardholder products with very small volumes. 56 +* Made //#3130#: Products that are not compliant with applicable CQM requirements – Requirement to maintain a valid CSI Letter// individual requirement to clarify that CQM non conformities must be covered by a CSI letter. 58 58 * //#3057#: 3 wheel Test Robustness for Interactive Cards (“IAC”) and ICC made without an ICM// — added clarification regarding re-using samples and regarding interpretation of test results with higher force than required. 59 59 * //#2041#: Fingerprint Sensor – Resistance to Abrasion// — Reworded to improve understanding. 60 -* //#3058#: Solidity – Adhesion of ICM to Card// — Separate minimum value defined for rupture of the ICM, provided the ICM remains attached in all corners of the ICC.59 +* //#3058#: Solidity – Adhesion of ICM to Card// — TBD 61 61 * //#2805#: Antenna Design – Minimum distance between mechanical personalization areas and the antenna in IL, ICC, IAC// — Wording revised to better accommodate IAC. 62 62 63 63 === Test methods === ... ... @@ -64,6 +64,4 @@ 64 64 65 65 * //#7010#: Pantone-Colours// — specified measurement parameters for colour measurement using spectrometer 66 66 * //#7120#: Security Devices (Hologram, PBM, magnetic stripe with hologram like surface, Signature Panel) – Adhesion, Aspect and Shape, Size and Positioning// — clarified that if cross-hatch necessary, a new sample shall be used 67 -* //#8093#: Temperature Cycling// — extended maximum period between removal from oven and verification of functionality to 72 h to accommodate weekends 68 -* #8230#: //Solidity – ICM Adhesion – Back of Card Spot Pressure Test// — Clarified positioning of centre of pressure for multicentric ICM, for example combining ISO/IEC 7816-2 contacts and a fingerprint sensor into a single ICM 69 69 * //#8310#: Resistance of a Fingerprint Sensor against Scratching// — Additional details specified