Last modified by Uwe Trueggelmann on 2025/02/15 00:20

Hide last authors
Uwe Trueggelmann 1.1 1 = Introduction =
2
3 Main changes in releases of the CQM Requirements:
4
5 = 2.19 =
6
7 Version 2.19 introduces the following main changes:
8
9 * Various clarifications in the QMS sections
Uwe Trueggelmann 1.2 10 * //#3100#: Cards made of materials other than newly produced PVC, and cards with an associated environmental claim – Requirement to maintain a valid CSI Letter// amended with provisions regarding environmental claims.//#3200#: CB, ICC, and IAC – Requirement to maintain a valid Mastercard Card Vendor Conformity Statement ("CVCS")// introduced
Uwe Trueggelmann 1.1 11 * For logo color measurement standard method is now CIEDE2000
12 * Major revision of #3036#: Hologram (including PBM), and the related test method, to align with Mastercard hologram supplier specification
13 * Revised provisions related to non-standard cards and CSI, e.g. #3100# Cards made of materials other than newly produced PVC – Requirement to maintain a valid CSI Letter, and equivalent for IAC added as #3110#
Uwe Trueggelmann 1.2 14 * Fully described the antenna current alternative in //#3064#: Reading Distance //, and other improvements to the text
Uwe Trueggelmann 1.1 15 * Simplifications for monitoring during Personalization
16 * Product structure revised, iacil and IAC now both separate products, and each have own worksheet in CQMAP.
17 * Revised requirements for Inlay for Interactive Cards (“iacil”) and Interactive Cards (“IAC”).
18
19 = 2.19.1 =
20
21 Version 2.19.1 introduces the following main changes:
22
23 * Major rewrite of section 2.4 #B400# CQM Products and CQM Labels, and Modular Certification
24 * Major rewrite of section 3.2 #C200# Determining the applicable CQM Products
25 * Changes to the naming and structure of products, including their variants
Uwe Trueggelmann 1.2 26
27 = 2.22 =
28
29 Version 2.22 introduces the following main changes:
30
31 * Adjustments to latest revisions of ISO/IEC 7810 and 10373-1.
Uwe Trueggelmann 2.1 32 * Full alignment of magnetic stripe requirements to ISO/IEC 7811-6, more stringent requirements in CQM removed.
Uwe Trueggelmann 1.2 33 * Expanding IAC requirements to accommodate fingerprint cards better.
34 * Clarifications and details to better handle subcontracting versus procuring from CQM certified suppliers, which has become more relevant with the more complex IAC supply chains.
Uwe Trueggelmann 2.2 35
36 = 3a =
37
38 Version 3a introduces the following main changes:
39
40 * Substantially increased granularity of products and processes for audit and certification scope.
Uwe Trueggelmann 2.3 41
42 === Quality Management System Requirements ===
43
Uwe Trueggelmann 2.4 44 * //#0654#: Design and Development – Product Qualification Report// — Lack of qualification data, and major NC without CSI letter now prohibit CQM certification
45 * IQC (Incoming Quality Control) to be assessed during CQM Audits for each CQM product and component, and not just once as part of the QMS
Uwe Trueggelmann 3.2 46 * //#0662#: Requirements for Products and Services – Determining the Requirements for Products and Services, Order Specification// — Order Specification appended to title to clarify that an Order Specification is required, verbiage added to clarify Order Specification
Uwe Trueggelmann 2.4 47 * //#0703# Release of Product and Services, Batch Yield Limit// — split into two independent requirements: //#0703#: Production and Service Provision – Release of Product and Services// and //#0707#: Production and Service Provision – Batch Yield Limit//; Batch Yield Limit now only applicable to products containing an IC.
48 * Requirements to implement SPC (//#0705#: Performance evaluation – Statistical Process Control//) and CpK (//#0811#: Performance evaluation – Process Capability//) restricted to ic icm iacicm bsm il iacil iac, that is, where processes involve wafer processing or IC packaging processes.
Uwe Trueggelmann 4.3 49 * A range of QMS requirements, primarily around the design process, moved from QMS worksheet in cqmAP to product specific worksheets, requiring the related processes to be in place for each CQM product, and to be verified during the CQM Audit for each CQM product.
Uwe Trueggelmann 2.3 50
51 === Product Requirements ===
52
Uwe Trueggelmann 3.2 53 * #3046#: Resistance to Chemicals — For CQM products and components where// #3058#: Solidity – Adhesion of ICM to Card// is required, clarified that one sample per solution shall be tested for //#3058#: Solidity – Adhesion of ICM to Card//
Uwe Trueggelmann 2.9 54 * //#3050#: ESD Conductivity – ESC — //Increased permitted levels of ESD conductivity
55 * //#3067#: Suitability for an Identification Notch — //Permitting greater tolerances
56 * //#3110#: IAC – Interactive Cards – Requirement to maintain a valid CSI Letter// — restricted to specific products, clarified to which products and components this requirement still applies.
57 * //#3120#: Pilot, innovative, and interactive cardholder identification products// – //requirement to undergo CQM Audits depending on annual production volume// — New requirement easing CQM audit and CQM certification requirements for innovative and interactive cardholder products with very small volumes.
58 * //#3130#: Products that are not compliant with applicable CQM requirements – Requirement to maintain a valid CSI Letter// — Now an individual requirement to clarify better that CQM non conformities must be covered by a CSI letter.
Uwe Trueggelmann 2.3 59 * //#3057#: 3 wheel Test Robustness for Interactive Cards (“IAC”) and ICC made without an ICM// — added clarification regarding re-using samples and regarding interpretation of test results with higher force than required.
60 * //#2041#: Fingerprint Sensor – Resistance to Abrasion// — Reworded to improve understanding.
Uwe Trueggelmann 2.13 61 * //#3058#: Solidity – Adhesion of ICM to Card// — Separate minimum value defined for rupture of the ICM, provided the ICM remains attached in all corners of the ICC.
Uwe Trueggelmann 2.3 62 * //#2805#: Antenna Design – Minimum distance between mechanical personalization areas and the antenna in IL, ICC, IAC// — Wording revised to better accommodate IAC.
63
64 === Test methods ===
65
66 * //#7010#: Pantone-Colours//  — specified measurement parameters for colour measurement using spectrometer
67 * //#7120#: Security Devices (Hologram, PBM, magnetic stripe with hologram like surface, Signature Panel) – Adhesion, Aspect and Shape, Size and Positioning// — clarified that if cross-hatch necessary, a new sample shall be used
Uwe Trueggelmann 2.13 68 * //#8093#: Temperature Cycling// — extended maximum period between removal from oven and verification of functionality to 72 h to accommodate weekends
Uwe Trueggelmann 2.14 69 * #8230#: //Solidity – ICM Adhesion – Back of Card Spot Pressure Test// — Clarified positioning of centre of pressure for multicentric ICM, for example combining ISO/IEC 7816-2 contacts and a fingerprint sensor into a single ICM
Uwe Trueggelmann 2.3 70 * //#8310#: Resistance of a Fingerprint Sensor against Scratching// — Additional details specified
© 2024 TruCert Assessment Services Inc.
V00-01